Energy Performance Certificate

43 Regent Square, E3 3HW

EPC Report

Energy rating

Current: 71 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 63 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 69 Potential: 69
Field Value
LMK KEY 6037-0127-0200-0446-5292
ADDRESS1 43 Regent Square
ADDRESS2
ADDRESS3
POSTCODE E3 3HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-03-16
LOCAL AUTHORITY E09000030
CONSTITUENCY E14001525
COUNTY
LODGEMENT DATE 2023-03-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 217
ENERGY CONSUMPTION POTENTIAL 182
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 190
LIGHTING COST POTENTIAL 147
HEATING COST CURRENT 541
HEATING COST POTENTIAL 341
HOT WATER COST CURRENT 587
HOT WATER COST POTENTIAL 280
TOTAL FLOOR AREA 79
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 43 Regent Square
LOCAL AUTHORITY LABEL Tower Hamlets
CONSTITUENCY LABEL Stratford and Bow
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2023-03-17 06:51:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 6071126
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew