Energy Performance Certificate

44 Stanch Hill Road, Sawtry, PE28 5XG

EPC Report

Energy rating

Current: 71 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 74 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 79 Potential: 79
Field Value
LMK KEY 6036-1122-0500-0237-9292
ADDRESS1 44 Stanch Hill Road
ADDRESS2 Sawtry
ADDRESS3
POSTCODE PE28 5XG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2026-02-13
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001298
COUNTY
LODGEMENT DATE 2026-02-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 151
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 41
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 516
HEATING COST POTENTIAL 435
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 45
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.23
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 44 Stanch Hill Road, Sawtry
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL Huntingdon
POSTTOWN HUNTINGDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2026-02-16 11:18:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100090118819
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew