Energy Performance Certificate

33 Bowman Drive, NE46 3BU

EPC Report

Energy rating

Current: 79 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 83 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 84 Potential: 84
Field Value
LMK KEY 6032-0627-4100-0469-4222
ADDRESS1 33 Bowman Drive
ADDRESS2
ADDRESS3
POSTCODE NE46 3BU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2022-03-21
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001285
COUNTY
LODGEMENT DATE 2022-03-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 142
ENERGY CONSUMPTION POTENTIAL 133
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 237
HEATING COST POTENTIAL 241
HOT WATER COST CURRENT 80
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 10.69
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33 Bowman Drive
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL Hexham
POSTTOWN HEXHAM
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2022-03-21 16:58:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10000847656
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000001
Address display
Nation ew