Energy Performance Certificate

41 Lambert Crescent, CW5 5UH

EPC Report

Energy rating

Current: 72 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 64 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 66 Potential: 66
Field Value
LMK KEY 5809-6321-5000-1147-1206
ADDRESS1 41 Lambert Crescent
ADDRESS2
ADDRESS3
POSTCODE CW5 5UH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-09-03
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001185
COUNTY
LODGEMENT DATE 2021-09-27
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 286
ENERGY CONSUMPTION POTENTIAL 268
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 328
HEATING COST POTENTIAL 255
HOT WATER COST CURRENT 274
HOT WATER COST POTENTIAL 170
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.386
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41 Lambert Crescent
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Crewe and Nantwich
POSTTOWN NANTWICH
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2021-09-27 16:12:41
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10013156566
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew