Energy Performance Certificate

71 Featherstone Court, Featherstone Road, UB2 5GQ

EPC Report

Energy rating

Current: 56 D | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 80 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 83 Potential: 83
Field Value
LMK KEY 5801-5247-7002-0103-1606
ADDRESS1 71 Featherstone Court
ADDRESS2 Featherstone Road
ADDRESS3
POSTCODE UB2 5GQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-07-08
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001209
COUNTY
LODGEMENT DATE 2023-07-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 166
ENERGY CONSUMPTION POTENTIAL 146
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 1004
HEATING COST POTENTIAL 931
HOT WATER COST CURRENT 333
HOT WATER COST POTENTIAL 280
TOTAL FLOOR AREA 46
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 91
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 91% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 71 Featherstone Court, Featherstone Road
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing Southall
POSTTOWN SOUTHALL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-07-09 21:53:56
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 12175561
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew