Energy Performance Certificate

141 Burgh Road, Gorleston, NR31 8AZ

EPC Report

Energy rating

Current: 28 F | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 16 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 52 Potential: 52
Field Value
LMK KEY 5800-8657-0922-1122-3323
ADDRESS1 141 Burgh Road
ADDRESS2 Gorleston
ADDRESS3
POSTCODE NR31 8AZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-07-25
LOCAL AUTHORITY E07000145
CONSTITUENCY E14001256
COUNTY
LODGEMENT DATE 2022-07-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 771
ENERGY CONSUMPTION POTENTIAL 309
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 130
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 124
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 2028
HEATING COST POTENTIAL 925
HOT WATER COST CURRENT 345
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 83
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 141 Burgh Road, Gorleston
LOCAL AUTHORITY LABEL Great Yarmouth
CONSTITUENCY LABEL Great Yarmouth
POSTTOWN GREAT YARMOUTH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-07-25 18:06:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100090835399
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew