Energy Performance Certificate

Chapters, Bridge Road, Bursledon, SO31 8AH

EPC Report

Energy rating

Current: 80 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 76 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 81 Potential: 81
Field Value
LMK KEY 5734-3529-8300-0065-3202
ADDRESS1 Chapters
ADDRESS2 Bridge Road
ADDRESS3 Bursledon
POSTCODE SO31 8AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-01-05
LOCAL AUTHORITY E07000086
CONSTITUENCY E14001263
COUNTY
LODGEMENT DATE 2024-01-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 102
ENERGY CONSUMPTION POTENTIAL 76
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 246
LIGHTING COST POTENTIAL 246
HEATING COST CURRENT 1612
HEATING COST POTENTIAL 1612
HOT WATER COST CURRENT 337
HOT WATER COST POTENTIAL 337
TOTAL FLOOR AREA 235
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Chapters, Bridge Road, Bursledon
LOCAL AUTHORITY LABEL Eastleigh
CONSTITUENCY LABEL Hamble Valley
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-01-05 09:35:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 41
LOW ENERGY FIXED LIGHT COUNT 41
UPRN 100060315753
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew