Energy Performance Certificate

11 The Blundens, Stoke By Nayland, CO6 4RH

EPC Report

Energy rating

Current: 78 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 94 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 Current: 94 95 Potential: 95
Field Value
LMK KEY 5634-2722-9409-0127-4206
ADDRESS1 11 The Blundens
ADDRESS2 Stoke By Nayland
ADDRESS3
POSTCODE CO6 4RH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-12-03
LOCAL AUTHORITY E07000200
CONSTITUENCY E14001494
COUNTY
LODGEMENT DATE 2024-12-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 94
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 19
ENERGY CONSUMPTION POTENTIAL 13
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 3
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 139
LIGHTING COST POTENTIAL 139
HEATING COST CURRENT 850
HEATING COST POTENTIAL 781
HOT WATER COST CURRENT 307
HOT WATER COST POTENTIAL 307
TOTAL FLOOR AREA 130
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 11 The Blundens, Stoke By Nayland
LOCAL AUTHORITY LABEL Babergh
CONSTITUENCY LABEL South Suffolk
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2024-12-03 15:50:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 100090998443
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew