Energy Performance Certificate

7 West Terrace, Staindrop, DL2 3JS

EPC Report

Energy rating

Current: 49 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 41 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 77 Potential: 77
Field Value
LMK KEY 5612-8126-8010-1550-7296
ADDRESS1 7 West Terrace
ADDRESS2 Staindrop
ADDRESS3
POSTCODE DL2 3JS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-06-10
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001101
COUNTY
LODGEMENT DATE 2022-06-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 292
ENERGY CONSUMPTION POTENTIAL 91
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 862
HEATING COST POTENTIAL 393
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 11
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 West Terrace, Staindrop
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL Bishop Auckland
POSTTOWN DARLINGTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-06-10 14:58:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100110715885
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000001
Address display
Nation ew