Energy Performance Certificate

7 White Horse, Uffington, SN7 7SE

EPC Report

Energy rating

Current: 62 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 39 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 56 Potential: 56
Field Value
LMK KEY 5337-7220-5309-0353-1296
ADDRESS1 7 White Horse
ADDRESS2 Uffington
ADDRESS3
POSTCODE SN7 7SE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-10-17
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001197
COUNTY
LODGEMENT DATE 2023-10-17
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 395
ENERGY CONSUMPTION POTENTIAL 249
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 190
LIGHTING COST POTENTIAL 190
HEATING COST CURRENT 1682
HEATING COST POTENTIAL 1384
HOT WATER COST CURRENT 318
HOT WATER COST POTENTIAL 212
TOTAL FLOOR AREA 105
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 White Horse, Uffington
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Didcot and Wantage
POSTTOWN FARINGDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2023-10-17 17:58:41
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 100120918582
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display
Nation ew