Energy Performance Certificate

17 Hunter Road, Dunsville, DN7 4FG

EPC Report

Energy rating

Current: 85 B | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 87 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 97 Potential: 97
Field Value
LMK KEY 5334-4233-2000-0124-8226
ADDRESS1 17 Hunter Road
ADDRESS2 Dunsville
ADDRESS3
POSTCODE DN7 4FG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-07-24
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001199
COUNTY
LODGEMENT DATE 2024-07-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 80
ENERGY CONSUMPTION POTENTIAL 17
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 127
LIGHTING COST POTENTIAL 127
HEATING COST CURRENT 381
HEATING COST POTENTIAL 381
HOT WATER COST CURRENT 143
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 100
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.15 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 17 Hunter Road, Dunsville
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster East and the Isle of Axholme
POSTTOWN Doncaster
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2024-07-24 10:08:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10095779435
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew