Energy Performance Certificate

17 School Road, Great Alne, B49 6HQ

EPC Report

Energy rating

Current: 88 B | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 B Current: 88 B 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 67 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 77 Potential: 77
Field Value
LMK KEY 5334-0429-3409-0679-4226
ADDRESS1 17 School Road
ADDRESS2 Great Alne
ADDRESS3
POSTCODE B49 6HQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 88
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-11-21
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001526
COUNTY
LODGEMENT DATE 2024-11-25
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 205
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 838
HEATING COST POTENTIAL 752
HOT WATER COST CURRENT 370
HOT WATER COST POTENTIAL 175
TOTAL FLOOR AREA 87
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17 School Road, Great Alne
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Stratford-on-Avon
POSTTOWN ALCESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-11-25 14:26:40
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100070205507
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000005
Address display
Nation ew