Energy Performance Certificate

18 Fore Street, Constantine, TR11 5AB

EPC Report

Energy rating

Current: 32 F | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 45 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 73 Potential: 73
Field Value
LMK KEY 5332-9522-2100-0446-3296
ADDRESS1 18 Fore Street
ADDRESS2 Constantine
ADDRESS3
POSTCODE TR11 5AB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-02-16
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001148
COUNTY
LODGEMENT DATE 2022-02-19
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 420
ENERGY CONSUMPTION POTENTIAL 172
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1379
HEATING COST POTENTIAL 403
HOT WATER COST CURRENT 188
HOT WATER COST POTENTIAL 109
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 38
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff, plus solar
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 18 Fore Street, Constantine
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Camborne and Redruth
POSTTOWN FALMOUTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-02-19 13:15:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100040061246
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew