Energy Performance Certificate

Flat 3, 320 Banbury Road, OX2 7ED

EPC Report

Energy rating

Current: 44 E | Potential: 44 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 44 E Potential: 44 E

Environmental impact (CO₂)

Current: 51 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 51 Potential: 51
Field Value
LMK KEY 5330-2539-2009-0548-0296
ADDRESS1 Flat 3
ADDRESS2 320 Banbury Road
ADDRESS3
POSTCODE OX2 7ED
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 44
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-11-18
LOCAL AUTHORITY E07000178
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2020-11-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 433
ENERGY CONSUMPTION POTENTIAL 433
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 37
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 765
HEATING COST POTENTIAL 765
HOT WATER COST CURRENT 273
HOT WATER COST POTENTIAL 273
TOTAL FLOOR AREA 41
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 1.48 W/m²K
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.50 W/m²K
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 3, 320 Banbury Road
LOCAL AUTHORITY LABEL Oxford
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN Oxford
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2020-11-18 13:59:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10012801358
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew