Energy Performance Certificate

18 Halstead Street, BL2 1AH

EPC Report

Energy rating

Current: 73 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 70 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 81 Potential: 81
Field Value
LMK KEY 5232-0727-3100-0357-4226
ADDRESS1 18 Halstead Street
ADDRESS2
ADDRESS3
POSTCODE BL2 1AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-03-23
LOCAL AUTHORITY E08000001
CONSTITUENCY E14001110
COUNTY
LODGEMENT DATE 2022-03-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 192
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 98
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 501
HEATING COST POTENTIAL 503
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18 Halstead Street
LOCAL AUTHORITY LABEL Bolton
CONSTITUENCY LABEL Bolton North East
POSTTOWN BOLTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-03-23 15:27:37
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100010884280
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew