Energy Performance Certificate

14 THE VALE, COVENTRY, CV3 1DW

EPC Report

Energy rating

Current: 77 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 77 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 88 Potential: 88
Field Value
LMK KEY 5219-1024-1000-0793-7296
ADDRESS1 14 THE VALE
ADDRESS2 COVENTRY
ADDRESS3
POSTCODE CV3 1DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-04-17
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001182
COUNTY
LODGEMENT DATE 2021-04-18
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 145
ENERGY CONSUMPTION POTENTIAL 65
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 363
HEATING COST POTENTIAL 367
HOT WATER COST CURRENT 86
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 THE VALE, COVENTRY
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry South
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-04-18 16:46:47
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070711545
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew