Energy Performance Certificate

9 Lilac Grove, Whitby, CH66 2PH

EPC Report

Energy rating

Current: 49 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 86 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 93 Potential: 93
Field Value
LMK KEY 5215-6065-1002-0192-1692
ADDRESS1 9 Lilac Grove
ADDRESS2 Whitby
ADDRESS3
POSTCODE CH66 2PH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-12-12
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001222
COUNTY
LODGEMENT DATE 2025-12-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 155
ENERGY CONSUMPTION POTENTIAL 82
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 2231
HEATING COST POTENTIAL 1387
HOT WATER COST CURRENT 1048
HOT WATER COST POTENTIAL 523
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 79
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Air source heat pump, warm air, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9 Lilac Grove, Whitby
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Ellesmere Port and Bromborough
POSTTOWN ELLESMERE PORT
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-12-23 12:39:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100010116565
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew