Energy Performance Certificate

Flat 29, Homecherry House, 86 High Road, IG10 4QU

EPC Report

Energy rating

Current: 71 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 62 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 66 Potential: 66
Field Value
LMK KEY 5212-0122-5000-0224-9296
ADDRESS1 Flat 29
ADDRESS2 Homecherry House
ADDRESS3 86 High Road
POSTCODE IG10 4QU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2022-02-14
LOCAL AUTHORITY E07000072
CONSTITUENCY E14001226
COUNTY
LODGEMENT DATE 2022-02-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 274
ENERGY CONSUMPTION POTENTIAL 249
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 346
HEATING COST POTENTIAL 261
HOT WATER COST CURRENT 302
HOT WATER COST POTENTIAL 181
TOTAL FLOOR AREA 58
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 29, Homecherry House, 86 High Road
LOCAL AUTHORITY LABEL Epping Forest
CONSTITUENCY LABEL Epping Forest
POSTTOWN LOUGHTON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2022-02-15 18:41:41
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100091250520
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew