Energy Performance Certificate

29 Lyttleton Street, B70 7SD

EPC Report

Energy rating

Current: 35 F | Potential: 46 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 46 E Potential: 46 E

Environmental impact (CO₂)

Current: 27 | Potential: 33
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 33 Potential: 33
Field Value
LMK KEY 5100-5037-0722-7520-3553
ADDRESS1 29 Lyttleton Street
ADDRESS2
ADDRESS3
POSTCODE B70 7SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 46
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-05-27
LOCAL AUTHORITY E08000028
CONSTITUENCY E14001574
COUNTY
LODGEMENT DATE 2025-06-01
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 33
ENERGY CONSUMPTION CURRENT 558
ENERGY CONSUMPTION POTENTIAL 471
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 7.0
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 1966
HEATING COST POTENTIAL 1971
HOT WATER COST CURRENT 200
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 84
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29 Lyttleton Street
LOCAL AUTHORITY LABEL Sandwell
CONSTITUENCY LABEL West Bromwich
POSTTOWN WEST BROMWICH
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2025-06-01 09:09:09
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 10008536416
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000005
Address display
Nation ew