Energy Performance Certificate

12 St. Georges Crescent, CH4 7AR

EPC Report

Energy rating

Current: 64 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 56 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 72 Potential: 72
Field Value
LMK KEY 5015-8036-2002-0079-1106
ADDRESS1 12 St. Georges Crescent
ADDRESS2
ADDRESS3
POSTCODE CH4 7AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2026-01-30
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2026-02-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 197
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 2562
HEATING COST POTENTIAL 1678
HOT WATER COST CURRENT 371
HOT WATER COST POTENTIAL 292
TOTAL FLOOR AREA 243
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 27
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.85
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 St. Georges Crescent
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN CHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-02-03 17:49:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 35
UPRN 100010028515
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000002
Address display
Nation ew