Energy Performance Certificate

22 Tir Morfa Road, SA12 7PF

EPC Report

Energy rating

Current: 95 A | Potential: 99 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 95 A Current: 95 A 99 A Potential: 99 A

Environmental impact (CO₂)

Current: 96 | Potential: 99
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 96 Current: 96 99 Potential: 99
Field Value
LMK KEY 5000-7953-0922-8321-3253
ADDRESS1 22 Tir Morfa Road
ADDRESS2
ADDRESS3
POSTCODE SA12 7PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 95
POTENTIAL ENERGY EFFICIENCY 99
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-02-25
LOCAL AUTHORITY W06000012
CONSTITUENCY W07000081
COUNTY
LODGEMENT DATE 2025-02-26
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 96
ENVIRONMENT IMPACT POTENTIAL 99
ENERGY CONSUMPTION CURRENT 4
ENERGY CONSUMPTION POTENTIAL -21
CO2 EMISSIONS CURRENT 0.0
CO2 EMISS CURR PER FLOOR AREA 0.6
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 351
HEATING COST POTENTIAL 319
HOT WATER COST CURRENT 352
HOT WATER COST POTENTIAL 238
TOTAL FLOOR AREA 75
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 Tir Morfa Road
LOCAL AUTHORITY LABEL Neath Port Talbot
CONSTITUENCY LABEL Aberafan Maesteg
POSTTOWN PORT TALBOT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-02-26 08:12:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100100631545
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew