Energy Performance Certificate

67 Maygreen Crescent, RM11 1EL

EPC Report

Energy rating

Current: 44 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 53 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 76 Potential: 76
Field Value
LMK KEY 5000-2463-0122-7194-3193
ADDRESS1 67 Maygreen Crescent
ADDRESS2
ADDRESS3
POSTCODE RM11 1EL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-09-16
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001448
COUNTY
LODGEMENT DATE 2022-01-21
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL 151
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1214
HEATING COST POTENTIAL 299
HOT WATER COST CURRENT 81
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION System built, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 67 Maygreen Crescent
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Romford
POSTTOWN HORNCHURCH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2022-01-21 11:44:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100021336050
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew