Energy Performance Certificate

Scilly Views, Sennen, TR19 7AD

EPC Report

Energy rating

Current: 76 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 78 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 86 Potential: 86
Field Value
LMK KEY 4834-6023-9400-0803-0292
ADDRESS1 Scilly Views
ADDRESS2 Sennen
ADDRESS3
POSTCODE TR19 7AD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-07-17
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2024-07-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 128
ENERGY CONSUMPTION POTENTIAL 76
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 168
LIGHTING COST POTENTIAL 168
HEATING COST CURRENT 1202
HEATING COST POTENTIAL 1203
HOT WATER COST CURRENT 725
HOT WATER COST POTENTIAL 456
TOTAL FLOOR AREA 175
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Scilly Views, Sennen
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN PENZANCE
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2024-07-19 20:48:34
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10093022945
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew