Energy Performance Certificate
6 Amberley Court, BD3 8BW
Energy rating
Current: 67 D | Potential: 71 C
Environmental impact (CO₂)
Current: 87
| Potential: 89
| Field | Value |
|---|---|
| LMK KEY | 4635-2029-9309-0478-8296 |
| ADDRESS1 | 6 Amberley Court |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | BD3 8BW |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 67 |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Not Recorded |
| INSPECTION DATE | 2025-11-18 |
| LOCAL AUTHORITY | E08000032 |
| CONSTITUENCY | E14001118 |
| COUNTY | — |
| LODGEMENT DATE | 2025-12-02 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 87 |
| ENVIRONMENT IMPACT POTENTIAL | 89 |
| ENERGY CONSUMPTION CURRENT | 193 |
| ENERGY CONSUMPTION POTENTIAL | 167 |
| CO2 EMISSIONS CURRENT | 1.0 |
| CO2 EMISS CURR PER FLOOR AREA | 18 |
| CO2 EMISSIONS POTENTIAL | 0.9 |
| LIGHTING COST CURRENT | 45 |
| LIGHTING COST POTENTIAL | 45 |
| HEATING COST CURRENT | 1047 |
| HEATING COST POTENTIAL | 866 |
| HOT WATER COST CURRENT | 398 |
| HOT WATER COST POTENTIAL | 398 |
| TOTAL FLOOR AREA | 59 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 1 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Controls for high heat retention storage heaters |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | — |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Controls for high heat retention storage heaters |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Excellent lighting efficiency |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | no corridor |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.26 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | mechanical extract, decentralised (MEV dc) |
| ADDRESS | 6 Amberley Court |
| LOCAL AUTHORITY LABEL | Bradford |
| CONSTITUENCY LABEL | Bradford East |
| POSTTOWN | BRADFORD |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2025-12-02 21:56:00 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| UPRN | 10010573509 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2025.csv |
| COUNTRY | England |
| REGION | E12000003 |
| Address display | — |
| Nation | ew |