Energy Performance Certificate

30 Spindlewood, Elloughton, HU15 1LL

EPC Report

Energy rating

Current: 68 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 62 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 76 Potential: 76
Field Value
LMK KEY 4600-2806-0622-0390-3443
ADDRESS1 30 Spindlewood
ADDRESS2 Elloughton
ADDRESS3
POSTCODE HU15 1LL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-04-10
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001250
COUNTY
LODGEMENT DATE 2024-04-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 214
ENERGY CONSUMPTION POTENTIAL 131
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 3.4
LIGHTING COST CURRENT 221
LIGHTING COST POTENTIAL 166
HEATING COST CURRENT 1622
HEATING COST POTENTIAL 1407
HOT WATER COST CURRENT 301
HOT WATER COST POTENTIAL 146
TOTAL FLOOR AREA 145
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 30 Spindlewood, Elloughton
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Goole and Pocklington
POSTTOWN BROUGH
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2024-04-11 06:21:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 200000623253
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew