Energy Performance Certificate

Flat 23, The Farriers, Pitts Lane, PO33 3XA

EPC Report

Energy rating

Current: 46 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 27 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 52 Potential: 52
Field Value
LMK KEY 4539-1329-1109-0169-2296
ADDRESS1 Flat 23
ADDRESS2 The Farriers
ADDRESS3 Pitts Lane
POSTCODE PO33 3XA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2021-11-11
LOCAL AUTHORITY E06000046
CONSTITUENCY E14001303
COUNTY
LODGEMENT DATE 2021-12-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 577
ENERGY CONSUMPTION POTENTIAL 319
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 995
HEATING COST POTENTIAL 455
HOT WATER COST CURRENT 185
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 59
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.4
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 23, The Farriers, Pitts Lane
LOCAL AUTHORITY LABEL Isle of Wight
CONSTITUENCY LABEL Isle of Wight East
POSTTOWN RYDE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-12-30 14:39:02
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100062043774
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew