Energy Performance Certificate

2 Winnipeg Close, BB2 7DX

EPC Report

Energy rating

Current: 64 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 58 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 77 Potential: 77
Field Value
LMK KEY 4516-6077-6002-0794-1202
ADDRESS1 2 Winnipeg Close
ADDRESS2
ADDRESS3
POSTCODE BB2 7DX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2023-04-15
LOCAL AUTHORITY E06000008
CONSTITUENCY E14001102
COUNTY
LODGEMENT DATE 2023-04-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 268
ENERGY CONSUMPTION POTENTIAL 149
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 165
LIGHTING COST POTENTIAL 165
HEATING COST CURRENT 1565
HEATING COST POTENTIAL 1283
HOT WATER COST CURRENT 351
HOT WATER COST POTENTIAL 197
TOTAL FLOOR AREA 89
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Winnipeg Close
LOCAL AUTHORITY LABEL Blackburn with Darwen
CONSTITUENCY LABEL Blackburn
POSTTOWN BLACKBURN
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2023-04-15 13:15:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100010766426
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000002
Address display
Nation ew