Energy Performance Certificate

21 Alexandra Road, CR0 6EY

EPC Report

Energy rating

Current: 1 G | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 16 | Potential: 39
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 39 Potential: 39
Field Value
LMK KEY 4510-1002-8002-0592-2106
ADDRESS1 21 Alexandra Road
ADDRESS2
ADDRESS3
POSTCODE CR0 6EY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-02-15
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001186
COUNTY
LODGEMENT DATE 2022-02-21
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 39
ENERGY CONSUMPTION CURRENT 625
ENERGY CONSUMPTION POTENTIAL 338
CO2 EMISSIONS CURRENT 12.4
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 6.7
LIGHTING COST CURRENT 133
LIGHTING COST POTENTIAL 146
HEATING COST CURRENT 3429
HEATING COST POTENTIAL 1316
HOT WATER COST CURRENT 998
HOT WATER COST POTENTIAL 132
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 85
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.89
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21 Alexandra Road
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Croydon East
POSTTOWN CROYDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-02-21 06:57:57
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100020581410
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew