Energy Performance Certificate

10a Stonehill Drive, Great Glen, LE8 9EL

EPC Report

Energy rating

Current: 61 D | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 58 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 62 Potential: 62
Field Value
LMK KEY 4500-3160-0322-0295-3773
ADDRESS1 10a Stonehill Drive
ADDRESS2 Great Glen
ADDRESS3
POSTCODE LE8 9EL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-03-16
LOCAL AUTHORITY E07000131
CONSTITUENCY E14001266
COUNTY
LODGEMENT DATE 2023-03-16
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 297
ENERGY CONSUMPTION POTENTIAL 271
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 131
LIGHTING COST POTENTIAL 131
HEATING COST CURRENT 1550
HEATING COST POTENTIAL 1356
HOT WATER COST CURRENT 457
HOT WATER COST POTENTIAL 457
TOTAL FLOOR AREA 73
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10a Stonehill Drive, Great Glen
LOCAL AUTHORITY LABEL Harborough
CONSTITUENCY LABEL Harborough, Oadby and Wigston
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-03-16 16:19:27
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100030477956
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000004
Address display
Nation ew