Energy Performance Certificate

193 Leam Terrace, CV31 1DW

EPC Report

Energy rating

Current: 31 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 34 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 88 Potential: 88
Field Value
LMK KEY 4439-9128-5000-0387-9226
ADDRESS1 193 Leam Terrace
ADDRESS2
ADDRESS3
POSTCODE CV31 1DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-08-23
LOCAL AUTHORITY E07000222
CONSTITUENCY E14001566
COUNTY
LODGEMENT DATE 2021-08-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 498
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 129
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 989
HEATING COST POTENTIAL 347
HOT WATER COST CURRENT 650
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 77
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 193 Leam Terrace
LOCAL AUTHORITY LABEL Warwick
CONSTITUENCY LABEL Warwick and Leamington
POSTTOWN LEAMINGTON SPA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-08-25 06:44:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100070248616
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew