Energy Performance Certificate

1 Lowbiggin, NE5 4PR

EPC Report

Energy rating

Current: 56 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 36 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 56 Potential: 56
Field Value
LMK KEY 4402-5528-7010-5744-0296
ADDRESS1 1 Lowbiggin
ADDRESS2
ADDRESS3
POSTCODE NE5 4PR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2022-08-14
LOCAL AUTHORITY E08000021
CONSTITUENCY E14001377
COUNTY
LODGEMENT DATE 2023-04-12
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 500
ENERGY CONSUMPTION POTENTIAL 310
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 85
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 1328
HEATING COST POTENTIAL 776
HOT WATER COST CURRENT 225
HOT WATER COST POTENTIAL 196
TOTAL FLOOR AREA 87
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 9.7
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Lowbiggin
LOCAL AUTHORITY LABEL Newcastle upon Tyne
CONSTITUENCY LABEL Newcastle upon Tyne Central and West
POSTTOWN NEWCASTLE UPON TYNE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-04-12 09:56:42
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 4510057754
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000001
Address display
Nation ew