Energy Performance Certificate

Apartment A.01.06, 1 Lewis Cubitt Park, N1C 4EJ

EPC Report

Energy rating

Current: 84 B | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 91 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 91 Potential: 91
Field Value
LMK KEY 4334-8534-6000-0675-7296
ADDRESS1 Apartment A.01.06
ADDRESS2 1 Lewis Cubitt Park
ADDRESS3
POSTCODE N1C 4EJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-04-15
LOCAL AUTHORITY E09000007
CONSTITUENCY E14001290
COUNTY
LODGEMENT DATE 2024-04-15
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 61
ENERGY CONSUMPTION POTENTIAL 61
CO2 EMISSIONS CURRENT 0.6
CO2 EMISS CURR PER FLOOR AREA 11
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 185
HEATING COST POTENTIAL 185
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 156
TOTAL FLOOR AREA 51
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.20 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Apartment A.01.06, 1 Lewis Cubitt Park
LOCAL AUTHORITY LABEL Camden
CONSTITUENCY LABEL Holborn and St Pancras
POSTTOWN London
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2024-04-15 13:14:54
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 5200877
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew