Energy Performance Certificate

12 WARREN CLOSE, WILBURTON, CB6 3QJ

EPC Report

Energy rating

Current: 97 A | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 A Current: 97 A 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 97 | Potential: 100
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 Current: 97 100 Potential: 100
Field Value
LMK KEY 4307-3260-9002-1520-0992
ADDRESS1 12 WARREN CLOSE
ADDRESS2 WILBURTON
ADDRESS3
POSTCODE CB6 3QJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 97
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-10-27
LOCAL AUTHORITY E07000009
CONSTITUENCY E14001224
COUNTY
LODGEMENT DATE 2020-11-24
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 97
ENVIRONMENT IMPACT POTENTIAL 100
ENERGY CONSUMPTION CURRENT 4
ENERGY CONSUMPTION POTENTIAL -15
CO2 EMISSIONS CURRENT 0.1
CO2 EMISS CURR PER FLOOR AREA 1
CO2 EMISSIONS POTENTIAL -0.4
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 119
HEATING COST CURRENT 1093
HEATING COST POTENTIAL 895
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 134
TOTAL FLOOR AREA 178
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 WARREN CLOSE, WILBURTON
LOCAL AUTHORITY LABEL East Cambridgeshire
CONSTITUENCY LABEL Ely and East Cambridgeshire
POSTTOWN WILBURTON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-11-24 14:16:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 10002593497
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew