Energy Performance Certificate

2 Coldharbour Court, Micheldever Road, SP10 2BL

EPC Report

Energy rating

Current: 65 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 47 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 59 Potential: 59
Field Value
LMK KEY 4300-0848-0022-4127-3223
ADDRESS1 2 Coldharbour Court
ADDRESS2 Micheldever Road
ADDRESS3
POSTCODE SP10 2BL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2022-02-24
LOCAL AUTHORITY E07000093
CONSTITUENCY E14001403
COUNTY
LODGEMENT DATE 2022-02-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 403
ENERGY CONSUMPTION POTENTIAL 295
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 653
HEATING COST POTENTIAL 391
HOT WATER COST CURRENT 192
HOT WATER COST POTENTIAL 192
TOTAL FLOOR AREA 60
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.35
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Coldharbour Court, Micheldever Road
LOCAL AUTHORITY LABEL Test Valley
CONSTITUENCY LABEL North West Hampshire
POSTTOWN ANDOVER
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2022-02-24 14:28:35
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 200000706401
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew