Energy Performance Certificate
29 Kennington Road, Fulwood, PR2 8BT
Energy rating
Current: 51 E | Potential: 72 C
Environmental impact (CO₂)
Current: 41
| Potential: 64
| Field | Value |
|---|---|
| LMK KEY | 4237-9029-0309-0526-2202 |
| ADDRESS1 | 29 Kennington Road |
| ADDRESS2 | Fulwood |
| ADDRESS3 | — |
| POSTCODE | PR2 8BT |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 51 |
| POTENTIAL ENERGY EFFICIENCY | 72 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2023-11-06 |
| LOCAL AUTHORITY | E07000123 |
| CONSTITUENCY | E14001433 |
| COUNTY | — |
| LODGEMENT DATE | 2023-11-10 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 41 |
| ENVIRONMENT IMPACT POTENTIAL | 64 |
| ENERGY CONSUMPTION CURRENT | 323 |
| ENERGY CONSUMPTION POTENTIAL | 184 |
| CO2 EMISSIONS CURRENT | 10 |
| CO2 EMISS CURR PER FLOOR AREA | 57 |
| CO2 EMISSIONS POTENTIAL | 5.8 |
| LIGHTING COST CURRENT | 265 |
| LIGHTING COST POTENTIAL | 265 |
| HEATING COST CURRENT | 4477 |
| HEATING COST POTENTIAL | 2848 |
| HOT WATER COST CURRENT | 316 |
| HOT WATER COST POTENTIAL | 278 |
| TOTAL FLOOR AREA | 179 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Programmer, TRVs and bypass |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 7 |
| NUMBER HEATED ROOMS | 7 |
| LOW ENERGY LIGHTING | 75 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Average |
| WALLS ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.44 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 29 Kennington Road, Fulwood |
| LOCAL AUTHORITY LABEL | Preston |
| CONSTITUENCY LABEL | Preston |
| POSTTOWN | PRESTON |
| CONSTRUCTION AGE BAND | England and Wales: 1950-1966 |
| LODGEMENT DATETIME | 2023-11-10 14:50:35 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 16 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| UPRN | 100010552728 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2023.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |