Energy Performance Certificate

156 Berkeley Road, B25 8NL

EPC Report

Energy rating

Current: 8 G | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 8 G Current: 8 G 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 22 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 81 Potential: 81
Field Value
LMK KEY 4200-6905-7222-6071-1323
ADDRESS1 156 Berkeley Road
ADDRESS2
ADDRESS3
POSTCODE B25 8NL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 8
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-07-30
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001100
COUNTY
LODGEMENT DATE 2022-08-02
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 631
ENERGY CONSUMPTION POTENTIAL 108
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 107
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 110
HEATING COST CURRENT 2633
HEATING COST POTENTIAL 460
HOT WATER COST CURRENT 1201
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 156 Berkeley Road
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Yardley
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-08-02 12:55:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100070292514
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display