Energy Performance Certificate

57 HAYDOCK DRIVE, CA2 4FA

EPC Report

Energy rating

Current: 85 B | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 86 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 95 Potential: 95
Field Value
LMK KEY 4200-3169-0132-3003-3393
ADDRESS1 57 HAYDOCK DRIVE
ADDRESS2
ADDRESS3
POSTCODE CA2 4FA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-07-06
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2021-07-06
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 81
ENERGY CONSUMPTION POTENTIAL 28
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 289
HEATING COST POTENTIAL 289
HOT WATER COST CURRENT 72
HOT WATER COST POTENTIAL 43
TOTAL FLOOR AREA 119
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 57 HAYDOCK DRIVE
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN CARLISLE
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2021-07-06 13:56:25
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10008715373
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew