Energy Performance Certificate

L02 The Rockingham, S63 6PX

EPC Report

Energy rating

Current: 59 D | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 63 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 63 Potential: 63
Field Value
LMK KEY 4159-3637-6100-3570-8292
ADDRESS1 L02 The Rockingham
ADDRESS2
ADDRESS3
POSTCODE S63 6PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2021-03-10
LOCAL AUTHORITY E08000018
CONSTITUENCY E14001436
COUNTY
LODGEMENT DATE 2021-03-11
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 305
ENERGY CONSUMPTION POTENTIAL 305
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 546
HEATING COST POTENTIAL 546
HOT WATER COST CURRENT 269
HOT WATER COST POTENTIAL 269
TOTAL FLOOR AREA 46
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.72 W/m²K
FLOOR ENERGY EFF Very Poor
FLOOR ENV EFF Very Poor
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.60 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS L02 The Rockingham
LOCAL AUTHORITY LABEL Rotherham
CONSTITUENCY LABEL Rawmarsh and Conisbrough
POSTTOWN WATH-UPON-DEARNE
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2021-03-11 13:16:28
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10095307102
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew