Energy Performance Certificate

7, Crow Lane, Wavendon, MK17 8AR

EPC Report

Energy rating

Current: 78 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 77 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 79 Potential: 79
Field Value
LMK KEY 4090-7743-0122-8000-3203
ADDRESS1 7, Crow Lane
ADDRESS2 Wavendon
ADDRESS3
POSTCODE MK17 8AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-12-04
LOCAL AUTHORITY E06000042
CONSTITUENCY E14001369
COUNTY
LODGEMENT DATE 2020-12-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 119
ENERGY CONSUMPTION POTENTIAL 110
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 127
LIGHTING COST POTENTIAL 127
HEATING COST CURRENT 1227
HEATING COST POTENTIAL 1228
HOT WATER COST CURRENT 204
HOT WATER COST POTENTIAL 139
TOTAL FLOOR AREA 185
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 81
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 81% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Crow Lane, Wavendon
LOCAL AUTHORITY LABEL Milton Keynes
CONSTITUENCY LABEL Milton Keynes Central
POSTTOWN MILTON KEYNES
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2020-12-04 20:01:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 25088814
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew