Energy Performance Certificate

27 SWALLOW RISE, SCAYNES HILL, RH17 7GL

EPC Report

Energy rating

Current: 86 B | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 86 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 91 Potential: 91
Field Value
LMK KEY 4090-6439-0732-7002-3003
ADDRESS1 27 SWALLOW RISE
ADDRESS2 SCAYNES HILL
ADDRESS3
POSTCODE RH17 7GL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-10-07
LOCAL AUTHORITY E07000228
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2020-10-07
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 66
ENERGY CONSUMPTION POTENTIAL 37
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 12
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 427
HEATING COST POTENTIAL 427
HOT WATER COST CURRENT 34
HOT WATER COST POTENTIAL 34
TOTAL FLOOR AREA 200
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, flue gas heat recovery
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.10 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 27 SWALLOW RISE, SCAYNES HILL
LOCAL AUTHORITY LABEL Mid Sussex
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN SCAYNES HILL
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2020-10-07 11:12:25
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10094497812
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew