Energy Performance Certificate

42 LANCASTER CLOSE, HAMSTREET, TN26 2JG

EPC Report

Energy rating

Current: 47 E | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 57 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 72 Potential: 72
Field Value
LMK KEY 4090-5712-0822-7090-3003
ADDRESS1 42 LANCASTER CLOSE
ADDRESS2 HAMSTREET
ADDRESS3
POSTCODE TN26 2JG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-10-19
LOCAL AUTHORITY E07000105
CONSTITUENCY E14001570
COUNTY
LODGEMENT DATE 2020-10-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 159
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 178
LIGHTING COST POTENTIAL 105
HEATING COST CURRENT 1169
HEATING COST POTENTIAL 997
HOT WATER COST CURRENT 236
HOT WATER COST POTENTIAL 138
TOTAL FLOOR AREA 160
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 42 LANCASTER CLOSE, HAMSTREET
LOCAL AUTHORITY LABEL Ashford
CONSTITUENCY LABEL Weald of Kent
POSTTOWN HAMSTREET
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-10-19 17:02:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200004385361
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew