Energy Performance Certificate

FLAT 48, STRAND HOUSE, WASHINGTON PARADE, L20 4SJ

EPC Report

Energy rating

Current: 73 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 76 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 78 Potential: 78
Field Value
LMK KEY 4039-1525-2000-0070-6226
ADDRESS1 FLAT 48
ADDRESS2 STRAND HOUSE
ADDRESS3 WASHINGTON PARADE
POSTCODE L20 4SJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-05-20
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001113
COUNTY
LODGEMENT DATE 2021-05-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 211
ENERGY CONSUMPTION POTENTIAL 187
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 342
HEATING COST POTENTIAL 329
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 13.4
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS FLAT 48, STRAND HOUSE, WASHINGTON PARADE
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Bootle
POSTTOWN BOOTLE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-05-20 14:09:21
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 41120439
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew