Energy Performance Certificate

4a The Drive, KT2 7NY

EPC Report

Energy rating

Current: 83 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 80 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 80 Potential: 80
Field Value
LMK KEY 4005-8836-1102-0097-2306
ADDRESS1 4a The Drive
ADDRESS2
ADDRESS3
POSTCODE KT2 7NY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2026-03-10
LOCAL AUTHORITY E09000021
CONSTITUENCY E14001445
COUNTY
LODGEMENT DATE 2026-03-13
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 69
ENERGY CONSUMPTION POTENTIAL 66
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 13
CO2 EMISSIONS POTENTIAL 7.0
LIGHTING COST CURRENT 192
LIGHTING COST POTENTIAL 192
HEATING COST CURRENT 2129
HEATING COST POTENTIAL 2129
HOT WATER COST CURRENT 246
HOT WATER COST POTENTIAL 246
TOTAL FLOOR AREA 574
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4a The Drive
LOCAL AUTHORITY LABEL Kingston upon Thames
CONSTITUENCY LABEL Richmond Park
POSTTOWN KINGSTON UPON THAMES
CONSTRUCTION AGE BAND England and Wales: 2012-2021
LODGEMENT DATETIME 2026-03-13 09:29:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 45
LOW ENERGY FIXED LIGHT COUNT 45
UPRN 128018435
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000007
Address display
Nation ew