Energy Performance Certificate

2 RUSSELL ROAD, NEWBURY, RG14 5LA

EPC Report

Energy rating

Current: 31 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 18 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 65 Potential: 65
Field Value
LMK KEY 3916-3060-3002-0292-8396
ADDRESS1 2 RUSSELL ROAD
ADDRESS2 NEWBURY
ADDRESS3
POSTCODE RG14 5LA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-12-11
LOCAL AUTHORITY E06000037
CONSTITUENCY E14001376
COUNTY
LODGEMENT DATE 2020-12-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 769
ENERGY CONSUMPTION POTENTIAL 224
CO2 EMISSIONS CURRENT 8.9
CO2 EMISS CURR PER FLOOR AREA 130
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1570
HEATING COST POTENTIAL 547
HOT WATER COST CURRENT 336
HOT WATER COST POTENTIAL 110
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 RUSSELL ROAD, NEWBURY
LOCAL AUTHORITY LABEL West Berkshire
CONSTITUENCY LABEL Newbury
POSTTOWN NEWBURY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-12-11 12:57:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100080233336
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew