Energy Performance Certificate

43 Jasmine Crescent, Trimdon, TS29 6QE

EPC Report

Energy rating

Current: 58 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 26 | Potential: 103
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 103 Potential: 103
Field Value
LMK KEY 3834-8529-4409-0339-3202
ADDRESS1 43 Jasmine Crescent
ADDRESS2 Trimdon
ADDRESS3
POSTCODE TS29 6QE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-11-01
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001382
COUNTY
LODGEMENT DATE 2024-11-06
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 103
ENERGY CONSUMPTION CURRENT 309
ENERGY CONSUMPTION POTENTIAL 130
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL -0.2
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 1251
HEATING COST POTENTIAL 1121
HOT WATER COST CURRENT 875
HOT WATER COST POTENTIAL 191
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, smokeless fuel
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL smokeless coal
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 45
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 43 Jasmine Crescent, Trimdon
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL Newton Aycliffe and Spennymoor
POSTTOWN TRIMDON STATION
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-11-06 07:50:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100110501606
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000001
Address display
Nation ew