Energy Performance Certificate

55 CHAPEL ROAD, CRUNDALE, SA62 4DZ

EPC Report

Energy rating

Current: 29 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 30 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 64 Potential: 64
Field Value
LMK KEY 3822-4319-4002-0295-0002
ADDRESS1 55 CHAPEL ROAD
ADDRESS2 CRUNDALE
ADDRESS3
POSTCODE SA62 4DZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2021-05-18
LOCAL AUTHORITY W06000009
CONSTITUENCY W07000100
COUNTY
LODGEMENT DATE 2021-06-10
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 607
ENERGY CONSUMPTION POTENTIAL 238
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 103
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 1163
HEATING COST POTENTIAL 500
HOT WATER COST CURRENT 402
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 56
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 70
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 70% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 55 CHAPEL ROAD, CRUNDALE
LOCAL AUTHORITY LABEL Pembrokeshire
CONSTITUENCY LABEL Mid and South Pembrokeshire
POSTTOWN HAVERFORDWEST
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-06-10 09:28:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 200003244302
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew