Energy Performance Certificate

20 Sterry Drive, KT7 0YN

EPC Report

Energy rating

Current: 32 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 41 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 83 Potential: 83
Field Value
LMK KEY 3735-2024-2500-0281-0226
ADDRESS1 20 Sterry Drive
ADDRESS2
ADDRESS3
POSTCODE KT7 0YN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-04-29
LOCAL AUTHORITY E07000207
CONSTITUENCY E14001230
COUNTY
LODGEMENT DATE 2025-05-06
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 353
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1960
HEATING COST POTENTIAL 575
HOT WATER COST CURRENT 534
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20 Sterry Drive
LOCAL AUTHORITY LABEL Elmbridge
CONSTITUENCY LABEL Esher and Walton
POSTTOWN THAMES DITTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-05-06 12:12:01
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100061324418
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew