Energy Performance Certificate

1 Regent Terrace, South Parade, DN1 2EE

EPC Report

Energy rating

Current: 1 G | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 10 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 Current: 10 72 Potential: 72
Field Value
LMK KEY 3734-8829-5300-0866-3292
ADDRESS1 1 Regent Terrace
ADDRESS2 South Parade
ADDRESS3
POSTCODE DN1 2EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-01-16
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001198
COUNTY
LODGEMENT DATE 2024-01-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 10
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 651
ENERGY CONSUMPTION POTENTIAL 128
CO2 EMISSIONS CURRENT 30
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 223
LIGHTING COST POTENTIAL 228
HEATING COST CURRENT 16883
HEATING COST POTENTIAL 2292
HOT WATER COST CURRENT 1141
HOT WATER COST POTENTIAL 211
TOTAL FLOOR AREA 277
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 3
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 4
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Regent Terrace, South Parade
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster Central
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-01-17 11:00:01
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 43
LOW ENERGY FIXED LIGHT COUNT 43
UPRN 10006574098
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew