Energy Performance Certificate
1, Avocet Drive, Angmering, BN16 4QL
Energy rating
Current: 84 B | Potential: 94 A
Environmental impact (CO₂)
Current: 85
| Potential: 95
| Field | Value |
|---|---|
| LMK KEY | 3637-5237-2000-0643-5202 |
| ADDRESS1 | 1 |
| ADDRESS2 | Avocet Drive |
| ADDRESS3 | Angmering |
| POSTCODE | BN16 4QL |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | A |
| CURRENT ENERGY EFFICIENCY | 84 |
| POTENTIAL ENERGY EFFICIENCY | 94 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2023-03-07 |
| LOCAL AUTHORITY | E07000224 |
| CONSTITUENCY | E14001599 |
| COUNTY | — |
| LODGEMENT DATE | 2023-03-07 |
| TRANSACTION TYPE | New dwelling |
| ENVIRONMENT IMPACT CURRENT | 85 |
| ENVIRONMENT IMPACT POTENTIAL | 95 |
| ENERGY CONSUMPTION CURRENT | 77 |
| ENERGY CONSUMPTION POTENTIAL | 11 |
| CO2 EMISSIONS CURRENT | 1.5 |
| CO2 EMISS CURR PER FLOOR AREA | 14 |
| CO2 EMISSIONS POTENTIAL | 0.3 |
| LIGHTING COST CURRENT | 167 |
| LIGHTING COST POTENTIAL | 167 |
| HEATING COST CURRENT | 501 |
| HEATING COST POTENTIAL | 501 |
| HOT WATER COST CURRENT | 193 |
| HOT WATER COST POTENTIAL | 111 |
| TOTAL FLOOR AREA | 113 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.19 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.25 W/m²K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.11 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Gas: mains gas |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.35 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | 1, Avocet Drive, Angmering |
| LOCAL AUTHORITY LABEL | Arun |
| CONSTITUENCY LABEL | Worthing West |
| POSTTOWN | LITTLEHAMPTON |
| CONSTRUCTION AGE BAND | 2021 |
| LODGEMENT DATETIME | 2023-03-07 12:19:26 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| UPRN | 10094569901 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 3 |
| Source file | certificates-2023.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |