Energy Performance Certificate

1 Vigar Mews, Auckland Road, CR3 5TU

EPC Report

Energy rating

Current: 105 A | Potential: 107 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 105 A Current: 105 A 107 A Potential: 107 A

Environmental impact (CO₂)

Current: 105 | Potential: 106
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 105 Current: 105 106 Potential: 106
Field Value
LMK KEY 3634-5835-6000-0684-7222
ADDRESS1 1 Vigar Mews
ADDRESS2 Auckland Road
ADDRESS3
POSTCODE CR3 5TU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 105
POTENTIAL ENERGY EFFICIENCY 107
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-05-24
LOCAL AUTHORITY E07000215
CONSTITUENCY E14001215
COUNTY
LODGEMENT DATE 2024-05-24
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 105
ENVIRONMENT IMPACT POTENTIAL 106
ENERGY CONSUMPTION CURRENT -41
ENERGY CONSUMPTION POTENTIAL -50
CO2 EMISSIONS CURRENT -0.7
CO2 EMISS CURR PER FLOOR AREA -7
CO2 EMISSIONS POTENTIAL -0.8
LIGHTING COST CURRENT 145
LIGHTING COST POTENTIAL 145
HEATING COST CURRENT 333
HEATING COST POTENTIAL 334
HOT WATER COST CURRENT 244
HOT WATER COST POTENTIAL 148
TOTAL FLOOR AREA 98
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1 Vigar Mews, Auckland Road
LOCAL AUTHORITY LABEL Tandridge
CONSTITUENCY LABEL East Surrey
POSTTOWN Caterham
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2024-05-24 14:59:20
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10096219312
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew